Steam Tables & Charts
Support
Questions, bug reports and feature ideas for Steam Tables & Charts go straight to the developer.
Contact support
For a bug, it helps to include your device and operating system, and to attach or describe the project, or the input pair and values, that gave the unexpected result.
Your name and email are used only to reply. See the privacy policy.
About the app
AppSteam Tables & Charts 1.1 for iPhone and iPad (iOS 18 or later), Apple Watch (watchOS 11 or later, with the iPhone app), Mac (macOS 15 or later) and Windows 10 (1809) or later
DeveloperJWE Software LLC
ContactUse the form on this page.
Frequently asked questions
Does the app need an internet connection or an account?
No. Steam Tables & Charts works fully offline, with no sign-in, ads or subscriptions.
Which formulation should I use?
IAPWS-IF97 (the default) is the industrial standard for power-plant and process calculations. IAPWS-95 is the scientific reference that IF97 was fitted to; it is slower but agrees with IF97 well within IF97’s stated uncertainty. Choose it for each project from the IF97 menu in the header of every chart and table; the Units menu is next to it.
Why is there no viscosity or conductivity for my point?
Transport properties aren’t defined for a liquid-vapor mixture, and the app gives them only inside the ranges of the IAPWS releases: from the melting line up to 900 °C (with IF97, above 800 °C only up to 50 MPa).
Where are my projects stored?
On your device: in the app on iPhone, iPad and Mac, and in your Windows user profile on a PC. They’re not sent anywhere, and we can’t see them. Save a project file to keep a copy or move it to another device. The Apple Watch app keeps its pinned states and settings on the watch.
Can I move a project between my iPhone, Mac and Windows PC?
Yes. Save or share the project as a .steamchart file and open it in Steam Tables & Charts on any of your devices. The same file works on iPhone, iPad, Mac and Windows. Between your Apple devices, Handoff can also pass the open project from one to the other. The app doesn’t sync on its own.
How do I enter gauge pressure?
Choose Gauge pressure in the Units menu in the header of any chart or table, and set the atmospheric pressure in Settings (101.325 kPa unless you change it). Points, processes, the chart readout and reports then show and take gauge pressure in your pressure unit, for example psig or kPa (g). Steam tables stay in absolute pressure, as printed tables are, and the batch lookup reads absolute pressures. Each project keeps its own choice.
Which spreadsheet files can the batch lookup import?
Excel (.xlsx, .xlsm, .xlsb and .xls), OpenDocument (.ods), and CSV, TSV or other text files, or a list you paste. A workbook with several sheets lets you choose the sheet. Put the units in the column headers, for example p (bar) or T [°F]; pressures are read as absolute. Numbers files can’t be read directly: in Numbers, choose File > Export To > Excel or CSV and import that file. Results export as CSV or Excel, and you can plot them on the charts as measured points.
Is there an Apple Watch app?
Yes. It comes with the iPhone app and needs watchOS 11 or later. Choose By pressure or By temperature and turn the Digital Crown through round values to read the saturation state, pin the states you check often, and choose SI or IP and IF97 or IAPWS-95 in its settings. Complications show saturation at a pressure or temperature you choose. It calculates on the watch itself, with the same core as the other apps.
How do I put my company and logo on the PDF report?
In Settings, under Company on reports, enter your company name and address, your name, and a PNG or JPEG logo; they print in the title block of every report you make on that device. For each project, add its report details in the Project tab: project number, client, revision, who prepared and checked it, with dates, and notes. Every page carries the project number, revision and initials.
What methods does the app use?
Thermodynamic properties follow IAPWS-IF97 (R7-97(2012)) with its backward equations, or IAPWS-95 (R6-95(2018)). Viscosity follows IAPWS R12-08, thermal conductivity IAPWS R15-11, the melting and sublimation curves IAPWS R14-08(2011), surface tension IAPWS R1-76(2014), ice Ih IAPWS R10-06(2009) and the ionization constant IAPWS R11-24; the expansion and Joule-Thomson coefficients and the isentropic exponent are derived from the formulation by IAPWS AN3-07(2018). Each is checked against the verification tables printed in its release, digit for digit. The app’s About section lists them.
Why can’t I place a point in the solid region of the phase diagram?
The melting and sublimation curves show where ice forms, but the property formulations start at 0 °C, so state points are limited to liquid, vapor and supercritical fluid. For ice itself, the Ice Ih tool gives its properties from IAPWS R10-06.
Can I use the results for final design?
Results are engineering estimates based on published standards. Always verify final designs against applicable codes, standards and manufacturer data.